| 0-10 VDC Output Signal |
Load must be at least 5 Kohms |
| 0-5 VDC Output Signal |
Load must be at least 2.5 Kohms |
| 4-20 mA Output Signal |
Load must not exceed 500 ohms |
| Accuracy (including linearity) |
±1.5% Full Scale |
| Certifications |
CE Approved 89/336/EEC (EN 55011 & EN 50082-1) 73/32/EEC Low Voltage Directive |
| Compatible Gases |
Clean, dry gases compatible with wetted materials |
| Electrical Connections |
Integrated 7-pin power/signal connector |
| Fitting Material |
Choose from acetal, brass, or stainless steel |
| Leak Integrity |
1 x 10-4 sccs of He |
| O-Ring Material |
Viton |
| Power |
12 VDC Models: 12 VDC @ 150 mA (12.5-15 VDC) 24 VDC Models: 24 VDC @ 80 mA (22-25 VDC) |
| Pressure Drop |
No more than 0.075 psid (5 mbar) |
| Pressure Rating |
150 psig (10.3 bar) |
| Pressure Sensitivity |
±0.02% F.S. or less per psi (per 69 mbar) |
| Ratings |
IP67 (NEMA 4) |
| Recommended Filtration |
100 microns or less |
| Reliability |
100,000 Hours MTBF (testing ongoing) |
| Repeatability |
±0.50% Full Scale |
| Settling Time |
Typically <1 second for 97% of final value |
| Temperature Rating |
Operating Range: 0 to 50șC Storage Range: 0 to 70șC |
| Temperature Sensitivity |
±0.15% F.S. or less per șC |
| Warm-Up Time |
Less than 5 minutes |
| Wetted Materials |
Aluminum 304 Stainless Steel 316 Stainless Steel |