| 0-5 VDC Output Signal |
Minimum 2.5 Kohm load |
| Accuracy (including linearity, best fit straight line) |
Standard: ±1.5% F.S. (10-100% rated flow) 2nd and 3rd gases (G9 or G10): ±3.0% F.S. |
| Body Leak Integrity (not including fittings) |
1 x 10-7 sccs of He |
| Certifications |
CE Approved 89/336/EEC (EN 55011 & EN 50082-1) 73/23/EEC Low Voltage Directive |
| Compatible Gases |
Clean, dry gases compatible with wetted materials |
| Display |
3.5 digit LCD flow rate display |
| Electrical Connections |
Integrated 36" (92 cm) cable, terminated with: Standard: 6-pin Mini-DIN (PS/2) style D1 Option: 9-pin D-Sub male D2 Option: 15-pin D-Sub male |
| External Setpoint (Command) Signal |
Integrated 2 Mohm load 0 VDC is zero flow |
| Fitting Material |
Choose from acetal, brass, or stainless steel |
| Internal Setpoint (Command) Signal |
Front panel adjustable |
| O-Ring Material |
Viton |
| Peak Power Consumption |
Standard: 12 VDC @ 500 mA (12.5-15 VDC) E Suffix: 24 VDC @ 260 mA (22-25 VDC) |
| Pressure Rating |
500 psig (34.5 bar) |
| Pressure Sensitivity |
±0.02% F.S. per psi (per 69 mbar) |
| Ratings |
IP10 (NEMA 1) |
| Recommended Filtration |
20 microns or less Optional inline filters available |
| Repeatability |
±0.25% Full Scale (10-100% rated flow) |
| Temperature Rating |
Operating: 5 to 55șC Storage: 0 to 70șC |
| Temperature Sensitivity |
±0.15% F.S. or less per șC |
| Typical Operating Differential Pressure |
15-45 psid (1-3 bar) |
| Typical Power Consumption |
Standard: 12 VDC @ 250 mA (12.5-15 VDC) E Suffix: 24 VDC @ 130 mA (22-25 VDC) |
| Valve |
Normally Closed Positive Shutoff up to 60 psig (4 bar) |
| Warm-Up Time |
Less than 5 minutes |
| Warranty |
1 year limited |
| Wetted Materials |
303 Stainless Steel 304 Stainless Steel 316 Stainless Steel Epoxy |