80SD Specifications

0-5 VDC Output Signal
Minimum 2.5 Kohm load
Accuracy (including linearity, best fit straight line)
Standard: ±1.5% F.S. (10-100% rated flow)
2nd and 3rd gases (G9 or G10): ±3.0% F.S.
Body Leak Integrity (not including fittings)
1 x 10-7 sccs of He
Certifications
CE Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
Compatible Gases
Clean, dry gases compatible with wetted materials
Display
3.5 digit LCD flow rate display
Electrical Connections
Integrated 36" (92 cm) cable, terminated with:
Standard: 6-pin Mini-DIN (PS/2) style
D1 Option: 9-pin D-Sub male
D2 Option: 15-pin D-Sub male
External Setpoint (Command) Signal
Integrated 2 Mohm load
0 VDC is zero flow
Fitting Material
Choose from acetal, brass, or stainless steel
Internal Setpoint (Command) Signal
Front panel adjustable
O-Ring Material
Viton
Peak Power Consumption
Standard: 12 VDC @ 500 mA (12.5-15 VDC)
E Suffix: 24 VDC @ 260 mA (22-25 VDC)
Pressure Rating
500 psig (34.5 bar)
Pressure Sensitivity
±0.02% F.S. per psi (per 69 mbar)
Ratings
IP10 (NEMA 1)
Recommended Filtration
20 microns or less
Optional inline filters available
Repeatability
±0.25% Full Scale (10-100% rated flow)
Temperature Rating
Operating: 5 to 55șC
Storage: 0 to 70șC
Temperature Sensitivity
±0.15% F.S. or less per șC
Typical Operating Differential Pressure
15-45 psid (1-3 bar)
Typical Power Consumption
Standard: 12 VDC @ 250 mA (12.5-15 VDC)
E Suffix: 24 VDC @ 130 mA (22-25 VDC)
Valve
Normally Closed
Positive Shutoff up to 60 psig (4 bar)
Warm-Up Time
Less than 5 minutes
Warranty
1 year limited
Wetted Materials
303 Stainless Steel
304 Stainless Steel
316 Stainless Steel
Epoxy



ZERO STABILITY



FITTING CHART