Flow Test Stand (App 10)
Application
Whether you have lines sizes of 1/8”, ½”, 3mm or 12 mm, we have a solution. Whether you have an aggressive acid or an inert gas to measure, we have a solution. Whether you need a thermal mass, microturbine, vortex, or magnetic flow meter or controller, we have a solution. Our online product configurator can help you find the right product.
McMillan Products Utilized
50K-10-E-A6-G0 Thermal Mass FLO-SENSOR
50-C-X Mating Cable
Description
McMillan Model 50K Thermal Mass FLO-SENSOR provides an analog output signal which is proportional to the flow rate. The maximum pressure rating is 150 PSIG. The Mating Cable with pigtail ends is connected to the power supply and programmable logic controller (PLC).
Operation
Regulated dry air (1-2 PSIG) flows through the Model 50K and reservoir to the atmosphere. A PLC monitors the 0-5 VDC output signal. A voltage signal of less than 3.5 VDC (7 Lpm) indicates an internal obstruction, and the defective piece is discarded. If the flow rate is above 7 Lpm the reservoir is moved to the next station for additional tests that do not make use of the Model 50K.