Model S113

SKU S113 Categories ,

McMillan S113 Flow Meters feature all-metal construction and are capable of measuring extremely low flow rates. Units are available that measure gases as low as 20 mL/min and as high as 10 L/min. Full scale accuracies of ± 3.0% are standard.

Flow Technology
Product Configurator
Is the Model S113 right for you? Use our product configurator to build the exact part number required for your application and request a quote with pricing and delivery time.
Loading file
  • Fullscreen
  • Wireframe
  • Zoom In
  • Zoom Out
  • Rotation
  • Screenshot
  • Help

Controls

×
  • Rotate with the left mouse button.
  • Zoom with the scroll button.
  • Adjust camera position with the right mouse button.
  • Double-click to enter the fullscreen mode.
  • On mobile devices swipe to rotate.
  • On mobile devices pinch two fingers together or apart to adjust zoom.
  • On mobile devices 3 finger horizontal swipe performs panning.

Description

McMillan S113 Flow Meters feature all-metal construction and are capable of measuring extremely low flow rates. Units are available that measure gases as low as 20 mL/min and as high as 10 L/min. Full scale accuracies of ± 3.0% are standard. Repeatable results are achieved using a Pelton-type microturbine wheel. This proven design has been providing precision results since 1988 and has developed a well-deserved reputation for continuous operational service or many years without failure.

Because of the compact size and affordable cost of these products, the S Series flow meters are suitable for a wide variety of industrial, commercial, laboratory and OEM applications. Some sample applications include measurement of hydrocarbon fluids, fuels, light oils, solvents, coolant, pesticides, acids, alkalis, and deionized water.

Several body types are available, including both plastic and metal. NIST Traceable certificates are available on all models. A backlit LCD display is integrated into each unit and is programmed to read in mL/min or L/min.

Features & Options

FLOW RANGES

Units are available that measure gas flow as low as 20 mL/min and as high as 10 L/min.

POWER

Most units may be specified to operate with either 12 VDC or 24 VDC power. Various power adapters are also available for use with 12 VDC versions.

SIGNAL OUTPUTS

S113 units come with a 0-5 VDC output.

ACCURACY/LINEARITY

All S113 units have a standard accuracy specification of ± 3% full scale including linearity. NIST traceable calibration certificates are optional.

FLUID CONNECTIONS

Units feature compression tube fittings. Fitting sizes may be selected as noted in the Product Configurator.

ELECTRICAL CONNECTIONS

Units have an integrated 4-pin male connector. To complete connections, either a cable assembly or power adapter should be ordered.

INTEGRATED DISPLAY

A flow rate display is integrated into each unit and is programmed to read in mL/min for ranges 3-6, and L/min for flow ranges 7-9.

Specifications

Compatible Gases
Accuracy (including linearity, best fit straight line)

±3.0% Full Scale

Repeatability

±0.5% Full Scale

Pressure Rating

40 psig (2.7 barg)

Temperature Rating

Operating Range: 5 - 55ºC
Storage Range: 0 - 70ºC

Temperature Sensitivity

±0.2% F.S. or less per ºC

Wetted Materials

Brass
PPS
304 SS
Epoxy
Glass
Sapphire
FKM

Recommended Filtration

25 microns or less

Compatible Media

Non-condensing, non-corrosive gases

0-5 VDC Output Signal

Non-isolated, 2500 ohm minimum load

Power

12 VDC units: 11.5 - 15 VDC @ 35 mA
24 VDC units : 22 - 25 VDC @ 35 mA

Response Time

Typically <30 seconds to 67% of final value

Certifications

CE Approved
89 / 336 / EEC (EN 55011 & EN 50082-1)
73 / 23 / EEC Low Voltage Directive
UKCA

Ratings

IP10 (NEMA 1)

Integrated Display

128x32 pixel backlit LCD

Downloads

CategoriesTitleSummaryFile SizeDownload

Related Products

McMillan S114 Flow Meters are constructed from stainless steel, rated for up to 500 psig (34.5 barg), and are capable of measuring extremely low liquid flow rates from 13 mL/min up to 10 L/min with a full scale accuracy of ± 1.0% or better.
McMillan S110 Flow Meters feature plastic construction and are capable of measuring extremely low flow rates. Units are available that measure gases as low as 20 mL/min and as high as 500 L/min. Full scale accuracies of ± 3.0% are standard.
McMillan RHODIUM Series Flow Controllers are capable of measuring and controlling virtually any clean, dry gas as low as 0 – 50 sccm or as high as 0 – 10 L/min. Repeatable results are achieved using a platinum-based micro-electromechanical system (MEMS) flow rate sensor device that is manufactured with extreme precision to ensure consistent results from unit to unit.

"*" indicates required fields

Download Request

Please fill out the form below to download your file.

This field is hidden when viewing the form
This field is hidden when viewing the form
This field is for validation purposes and should be left unchanged.